Operating Temperature: 0 to 60☌ (32 to 140☏) Storage Temperature: -40 to 85 ☌ (-40 to 185☏) Ambient Relative Humidity: 5 to 95% (non-condensing) Altitude: Up to 2000 m (795 hPa), higher altitudes on demand Moxa mb3180 Power Requirements Housing: Metal, IP30 protection Weight: 340 g Dimensions: Without ears: 22 x 52 x 80 mm (0.87 x 2.05 x 3.15 in) With ears: 22 x 75 x 80 mm (0.87 x 2.95 x 3.15 in) Environmental Limits #Modbus server tcp serial moxa windows#RS232: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND RS422: Tx+, Tx-, Rx+, Rx-, GND RS485-4w: Tx+, Tx-, Rx+, Rx-, GND RS485-2w: Data+, Data-, GND MGate mb3180 SoftwareĬonfiguration Options: Web Console, Serial Console, Telnet Console, Windows Utility Utilities: MGate Manager for Windows 2000/XP/2003/Vista/Server (x86/圆4), Windows Server 2008 R2/2012 (圆4) Multi-master and Multi-drop: Master mode: 32 TCP slaves Slave mode: 16 TCP masters (request queue 32-deep for each master) Support: Smart Routing, MXview, SNMP v1 (read only) Physical Characteristics #Modbus server tcp serial moxa software#Protocol: Modbus RTU/ASCII Slave/Master Number of Ports: 1 Serial Standards: RS232/422/485, software selectable Connectors: DB9 male ESD Protection: 15 kV for all signals RS485 Data Direction Control: ADDC® (automatic data direction control) Serial Communication Parametersĭata Bits: 7, 8 Stop Bits: 1, 2 Parity: None, Even, Odd, Space, Mark Flow Control: RTS/CTS, DTR/DSR (RS232 only) Baudrate: 50 bps to 921.6 kbps Serial Signals Protocol: Modbus TCP Number of Ports: 1 Speed: 10/100 Mbps, Auto MDI/MDIX Connector: 8-pin RJ45 Magnetic Isolation Protection: 1.5 kV (built-in) Serial Interface The MGate™ MB3000 gateways can effectively connect a high density of Modbus nodes to the same network. The MB3180 offer features that make network integration easy, customizable, and compatible with almost any Modbus network. In addition, the gateways support simultaneously connecting serial and Ethernet. The gateways provide both serial-to-Ethernet communication and serial (master) to serial (slave) communications. With this model, Modbus serial slave devices can be seamlessly incorporated into an existing Modbus TCP network, and Modbus TCP slaves can be made accessible to serial masters. The MGate MB3170 and MB3270 are 1 and 2-port Modbus gateways, respectively, that convert between Modbus TCP, ASCII, and RTU communications protocols. Moxa MGate mb3180 is designed for easy integration of Modbus TCP and RTU/ASCII networks. With these models, Modbus serial slave devices can be seamlessly incorporated into an existing Modbus TCP network, and Modbus TCP slaves can be made. For RTU/ASCII masters, up to 32 TCP slaves are supported. Up to 16 simultaneous Modbus TCP masters are supported, with up to 31 RTU/ASCII slaves per serial port. ![]() The Moxa MB3180 is standard Modbus gateway that convert between Modbus TCP and Modbus RTU/ASCII protocols. Whether wired or wireless, single or multiple serial ports, Moxa’s Modbus TCP gateway solutions connect Modbus RTU, DNP3, J1939, and PROFIBUS devices to Modbus TCP networks, making configuration, troubleshooting, and conversion quick and easy.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |